DB15 Cable (2-row 15-pin)

https://www.linkcnc.net/web/image/product.template/2456/image_1920?unique=5eee4bf

¥ 14.30 14.3 CNY ¥ 14.30

Not Available For Sale

Reference weight: approx. 140 g
  • Color
  • Shape

This combination does not exist.

Prices exclude shipping. Submit your order and we will email you a formal quote.

Returns & refunds
7-day returns · custom products excluded
Shipping cost quoted with your order

Wire and cable · 2 colours · 3 styles · 6 options in stock

Hook-up wire and cable for machine wiring — gauge, cores and flexibility. The parameters are listed in order of importance: the one at the top decides the most, and no amount of care further down makes up for getting it wrong.

This page lists 6 options: Colour / finish Black / White, Style / variant Business to business / Male to female / Mother to mother. From ¥14.3.

The parts of this item

The parts of a cable or electrical part

Figure 1 — Cable needs three things: cores, gauge, length — connectors are extra; leave them out and you crimp your own

What each parameter decides

Every parameter below shows the real range available on this page, and what goes wrong if you pick it wrong. Work through them in this order and you will not go far wrong.

ParameterAvailable hereWhat it decidesIf you get it wrong
Colour / finishBlack / Whiteappearance and surface finish — usually not the sizeonly looks and price change; it still fits
Style / variantBusiness to business / Male to female / Mother to motherthe structural and shape differencesit will not fit, or it will not do the job your mechanism needs

How to choose, step by step

  1. Type — Shielded or unshielded, flexible or solid core.

How the options on this page are distributed

How the 6 options on this page are distributed

Figure 2 — how the 6 options on this page are spread across each parameter: the bars on the left show how many options sit in each band, the panel on the right shows the real range of every parameter and how many steps it has.

Variant quick reference

Colour / finishStyle / variantPart no.
BlackMother to motherEG-051-BK-FF
BlackMale to femaleEG-051-BK-MF
BlackBusiness to businessEG-051-BK-MM
WhiteMother to motherEG-051-WH-FF
WhiteMale to femaleEG-051-WH-MF
WhiteBusiness to businessEG-051-WH-MM

Reading the part numbers

Part no.Configuration
EG-051-BK-FFColour / finish Black · Style / variant Mother to mother
EG-051-BK-MFColour / finish Black · Style / variant Male to female
EG-051-BK-MMColour / finish Black · Style / variant Business to business

You can order by part number or by selecting the parameters. The part number is fastest, but it does not always encode every parameter — the selector on this page is the authority.

6 common mistakes

  1. Undersized wire gets hot. Size by current, not by what fits the terminal.
  2. Drag chain needs flexible cable. Ordinary wire work-hardens and breaks its strands after a few hundred thousand cycles.
  3. Keep signal and power apart. Running them in parallel couples noise into the signal and you chase it as a "random" fault.
  4. Stranded wire needs ferrules in screw terminals. Bare strands creep and the joint loosens.
  5. Measure before you order. Take the old part off and measure it, or send us a photo with the caliper reading — that beats guessing from a model number every time.
  6. Everything here is in millimetres. Where a size is imperial, convert it: 1" = 25.4 mm, 1/4" = 6.35 mm, 3/32" = 2.38 mm.

When to replace it

You do not replace this until it fails — but "still looks usable" and "still reliable" are two different things. Any one of these and it is time:

  • Insulation damaged with copper visible.
  • Broken strands at a bend — a meter shows intermittent continuity when you flex it.

Fitting and use

Before wiring

  • Confirm voltage and polarity first. Reversed, it is destroyed on the first switch-on — there is no second chance. DC parts especially.
  • Wire with the power off, then check continuity and insulation with a meter before you apply power.
  • Crimp or tin the wire ends. Twisting bare strands onto a terminal gives a high-resistance joint that heats up.

Mounting

  • Leave the heated parts some air. Do not mount them against plastic or against the cable run.
  • Parts with a direction (fans, check valves) have an arrow. Reversed, you lose most of the airflow or flow.
  • Fasten it properly. Vibration loosens terminals, and loose terminals are the most common electrical failure there is.

First power-up

  • First power-up from a current-limited supply, or through a fuse. If something is wrong the damage stays small.
  • Run it unloaded first, measure current and temperature, then add load.
  • After 30 minutes feel the terminals and the cable. Anything noticeably warm means high contact resistance — re-crimp it.

Three things not to do

  • Do not connect or disconnect under power unless it is explicitly rated for hot-plug. The arc damages the terminals.
  • Do not run above the rating. It works for a while, then it does not.
  • Do not skip the earth or the fuse. You save a few yuan and risk the machine.

Matching parts

  • Ferrules, heat shrink and drag chain

Lead time, custom work and shipping

  • Stock sizes: dispatched in 1–2 working days, subject to stock
  • Custom: non-standard sizes, materials and treatments are possible — send quantity and drawing
  • Shipping: from Shenzhen; domestic courier by default, DHL or dedicated line for export
  • Volume: quantity pricing available, contact us for a quote

If you cannot find the size you need, or you are not sure which one fits, send us the problem you are solving — what machine it goes on, the dimensions of the part you have, what it has to achieve — and we will match it.

Home Products OEM & Custom About Us Contact Us Catalog +86 (0755) 23221210